Panel Testing, Load, & Spec Data for TL 1750

Testing Data For American Architectural TL 1750 Roof Panel

Click on a test to go directly to it.

Theoretical Allowable Load Tables For American Architectural TL 1750 Roof Panel
Click on a load table to go directly to it.
Metal Roof Panel Specifications:

Project No. T109-03
Test Date 1/22/03
Ambient Temp. = 57.0 deg. F
Barometric Pressure = 30.11" Hg
ASTM E-1680-95
Air Leakage Test
Summary
Test Specimen Static Pressure Differential
(psf)
Air Leakage Rate
(cfm/lf)
Air Leakage Rate
(cfm/sf)
TL 1750 1-3/4" +1.57 0.002 0.001
High Integral Panel -1.57 0.009 0.006
24 GA x 18" w +6.24
-6.24
0.004
0.011
0.003
0.007

Project No. T109-03
Test Date 1/22/03
Panel Surface Temp. Prior to Test = 67 deg. F
Panel Surface Temp. During Test = 47 deg. F
Ponded Water Depth During Test = 1/2"
ASTM E-1646-95
Water Penetration Test
Summary
Test Specimen Static Pressure Differential
(psf)
Rate Test Duration Water Infiltration
TL 1750 1-3/4" 6.75 psf 5 gal./hr./sq. ft. 15 min. None
High Integral Panel 9.75 psf 5 gal./hr./sq. ft. 15 min. None
24 GA x 18" w 12.0 psf 5 gal./hr./sq. ft. 15 min. None

Return to the top.

Theoretical Allowable Live Load Tables For
American Architectural TL 1750 Roof Panel 22 GA

Theoretical Allowable Live Load (psf)

Panel
Gage
Panel
Width
# of
Equal
Spans
Span (ft.)
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
22
GA
Steel
18
in.
1 326 247 171 125 96 75 61 50
2 202 131 91 67 51 40 32 26
3 234 151 106 78 59 46 37 31

Theoretical Allowable Uplift Load Tables For
American Architectural TL 1750 Roof Panel 22 GA

Theoretical Allowable Uplift Load (psf)

Panel
Gage
Panel
Width
# of
Equal
Spans
Span (ft.)
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
22
GA
Steel
18
in.
1 284 182 127 94 73 58 47 39
2 332 266 219 164 127 102 83 69
3 363 291 207 153 118 94 77 64

Theoretical Allowable Live Load Tables For
American Architectural TL 1750 Roof Panel 24 GA

Theoretical Allowable Live Load (psf)

Panel
Gage
Panel
Width
# of
Equal
Spans
Span (ft.)
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
24
GA
Steel
18
in.
1 197 158 131 97 74 58 47 39
2 155 100 70 51 39 31 25 20
3 179 116 81 59 45 36 29 23

Theoretical Allowable Uplift Load Tables For
American Architectural TL 1750 Roof Panel 24 GA

Theoretical Allowable Uplift Load (psf)

Panel
Gage
Panel
Width
# of
Equal
Spans
Span (ft.)
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
24
GA
Steel
18
in.
1 217 140 98 72 56 44 36 30
2 229 183 153 127 98 79 64 54
3 250 200 159 117 90 72 59 49

Return to the top.